Thursday, November 22, 2007

Changing the Standard GUI Status

The GUI status of a selection screen is generated by the system. The SET PF-STATUS
statement in the PBO event of the selection screen has no effect on the standard GUI status. If
you want to use your own GUI status for a selection screen or deactivate functions in the
standard GUI status in exceptional cases, you can use one of the following function modules in
the PBO event of the selection screen:

---> RS_SET_SELSCREEN_STATUS
Sets another GUI status defined in the same ABAP program, or deactivates functions of
the standard GUI status.

--->RS_EXTERNAL_SELSCREEN_STATUS
Sets a GUI status defined in an external function group. You must use the SET PFSTATUS
statement to set the status in a special function module in this function group.
You must pass the name of the function module that sets the status as a parameter to
the function module RS_EXTERNAL_SELSCREEN_STATUS.

For further information, refer to the function module documentation.

REPORT demo_sel_screen_status.
DATA itab TYPE TABLE OF sy-ucomm.
PARAMETERS test(10) TYPE c.
AT SELECTION-SCREEN OUTPUT.
APPEND: 'PRIN' TO itab,
'SPOS' TO itab.
CALL FUNCTION 'RS_SET_SELSCREEN_STATUS'
EXPORTING
p_status = sy-pfkey
TABLES
p_exclude = itab.

In this example, the Print and Save as variant functions are deactivated. To find out
the function codes of the standard GUI status, choose System  Status and doubleclick
the GUI status field.

No comments:

Blog Archive